小舞两腿乳液自慰羞羞漫画_麻豆精品无码国产在线果冻_无码av免费毛片一区二区_欧洲图色

客戶咨詢熱線:
13511666605
首頁 > 產品中心 > 分析(檢測)儀器系列 > 電導率儀 > DDS-307數顯臺式電導率儀

數顯臺式電導率儀

簡(jian)要(yao)描述:DDS-307數顯臺式電(dian)(dian)(dian)(dian)(dian)導率儀測(ce)試(shi)電(dian)(dian)(dian)(dian)(dian)導的方(fang)法,是通過由振蕩(dang)器(qi)產生(sheng)的交流(liu)電(dian)(dian)(dian)(dian)(dian)壓加(jia)在電(dian)(dian)(dian)(dian)(dian)極(ji)上(加(jia)交流(liu)電(dian)(dian)(dian)(dian)(dian)壓的目的是為(wei)了避免引起電(dian)(dian)(dian)(dian)(dian)極(ji)的極(ji)化),電(dian)(dian)(dian)(dian)(dian)導池內產生(sheng)電(dian)(dian)(dian)(dian)(dian)流(liu),此電(dian)(dian)(dian)(dian)(dian)流(liu)與被測(ce)溶液的電(dian)(dian)(dian)(dian)(dian)導率成正比,經(jing)電(dian)(dian)(dian)(dian)(dian)流(liu)-電(dian)(dian)(dian)(dian)(dian)壓變換(huan)、放大、檢波,變換(huan)為(wei)直流(liu)電(dian)(dian)(dian)(dian)(dian)壓,通過溫(wen)度補償等,Z后經(jing)A/D轉(zhuan)換(huan)器(qi)轉(zhuan)換(huan)成數字信號,通過微(wei)電(dian)(dian)(dian)(dian)(dian)腦顯示(shi)。整個過程均由微(wei)電(dian)(dian)(dian)(dian)(dian)腦控制和(he)處理。歡迎新(xin)來顧客,量(liang)大優惠(hui)!

  • 產品型號:DDS-307
  • 廠商性質:生產廠家
  • 更新時間:2021-04-12
  • 訪(fang)  問  量:749
詳細介紹

數顯臺式電導率儀主要(yao)技術指標
測量范(fan)圍:電導率: (0~199.9)μs/cm ;(200~1999)μs/cm ;
                    (2.00~19.99)ms/cm ;(20.0~199.9)ms/cm ;
分(fen)辨率: 0.1/1μs/cm ;0.01/0.1ms/cm ;
準 確 度: 電計:±1.0%FS;配套:±1.5%FS
溫度補償(chang)范圍:0~50℃  (手動)
溫 度 系(xi) 數: 2.0%/℃
可選配電極(ji)規格常數: 0.1、1、10
 數據儲(chu)存:50組
 儲存內容:編號(hao)、測(ce)(ce)量值、測(ce)(ce)量單位和溫度值
 電(dian)源:DC9V適(shi)配器
 外形尺寸及(ji)重量: 220×200×80mm(長×寬(kuan)×高(gao))    1.7 kg
數顯臺式電導率儀工作(zuo)條件(jian)
環境(jing)溫度(du):  5~35℃    相對濕度(du):  <85%        
供電(dian)電(dian)源: 220V±10%        50Hz ± 1Hz 
無顯著(zhu)的振動
除地磁(ci)場(chang)外(wai)無(wu)其他(ta)強磁(ci)場(chang)干擾。
工作(zuo)原理(li):                                             在(zai)電解(jie)質(zhi)溶液中,帶電離子在(zai)電場作(zuo)用下產生移動而傳遞(di)電流。其導(dao)(dao)電能力(li)以電導(dao)(dao)度G來(lai)表示,其值(zhi)為電阻的倒(dao)數(shu)。 即 G=1/R
測試電導度大小(xiao)的(de)(de)方法,可用兩(liang)個(ge)金屬(shu)極(ji)板(ban)組成(cheng)的(de)(de)電極(ji)插(cha)入溶液中,形成(cheng)一個(ge)電導池,測出兩(liang)極(ji)板(ban)間(jian)的(de)(de)電阻(zu)。根據歐姆(mu)定律,該電阻(zu)值(zhi)與(yu)極(ji)板(ban)之間(jian)的(de)(de)距離L(cm)成(cheng)正比(bi),與(yu)極(ji)板(ban)的(de)(de)面積A(cm2)成(cheng)反比(bi)。 即 R=ρ•L/A 
ρ為電(dian)阻(zu)率 ,令其倒數為電(dian)導率并以(yi)K表示(shi),則(ze)K=1/ρ
對于某一支電(dian)(dian)極(ji)(ji)(ji)而言(yan),電(dian)(dian)極(ji)(ji)(ji)極(ji)(ji)(ji)板之(zhi)間的(de)有效(xiao)距離(li)L與極(ji)(ji)(ji)板的(de)面積(ji)A之(zhi)比稱為(wei)這支電(dian)(dian)極(ji)(ji)(ji)的(de)電(dian)(dian)極(ji)(ji)(ji)常(chang)數(shu),用J表示, 即(ji)J=L/A 
根據以上(shang)各式可得: 
    G=K/J    即(ji)K=G•J
電導G的單(dan)位為西(xi)門子,單(dan)位符號是S。
 1S=103ms=106μS
電導率K的常用(yong)單位為mS/cm及μS/cm。
本儀器測(ce)試電(dian)(dian)導的(de)方法,是通過由振(zhen)蕩器產生的(de)交(jiao)流(liu)(liu)電(dian)(dian)壓(ya)加在電(dian)(dian)極(ji)(ji)上(加交(jiao)流(liu)(liu)電(dian)(dian)壓(ya)的(de)目(mu)的(de)是為(wei)了避免引起電(dian)(dian)極(ji)(ji)的(de)極(ji)(ji)化(hua)),電(dian)(dian)導池內產生電(dian)(dian)流(liu)(liu),此(ci)電(dian)(dian)流(liu)(liu)與被測(ce)溶液的(de)電(dian)(dian)導率成正(zheng)比,經電(dian)(dian)流(liu)(liu)-電(dian)(dian)壓(ya)變換(huan)、放大、檢波,變換(huan)為(wei)直流(liu)(liu)電(dian)(dian)壓(ya),通過溫(wen)度補(bu)償等(deng),zui后經A/D轉(zhuan)換(huan)器轉(zhuan)換(huan)成數(shu)字(zi)信(xin)號(hao),通過微電(dian)(dian)腦(nao)(nao)顯(xian)示(shi)。整個過程均由微電(dian)(dian)腦(nao)(nao)控制和處理(li)。
儀器基(ji)本說明                                 
1.儀器(qi)操(cao)作按鍵說明
儀(yi)器共有6個操作鍵(jian)
○1“開關”—開關鍵,按鍵開關電(dian)源。
○2“校準”—校準鍵,在測量狀(zhuang)態時,按鍵進(jin)入儀(yi)器(qi)校準模式(shi)。
○3“功能”—功能鍵(jian),按鍵(jian)進入參數(shu)設置模式P1,P2,P3…
○4“∧、∨”—增(zeng)加(jia)鍵(jian)和減少(shao)鍵(jian)。
a、在測量狀態下,手動溫度補償時按鍵增加(jia)或減少(shao)溫度值,短按一次改變0.1℃,長按時溫度快(kuai)速改變。
b、在(zai)參數設置狀(zhuang)態(tai)時(shi),按鍵改變(bian)數字或ON/OFF狀(zhuang)態(tai)。
○5“儲(chu)存(cun)/提取”—儲(chu)存(cun)和提取按鍵(jian),用于(yu)測量值(zhi)的儲(chu)存(cun)和提取。
○6“確(que)(que)認(ren)”—確(que)(que)認(ren)鍵,在校準狀態(tai)(tai)或參數設(she)置狀態(tai)(tai)時(shi)按鍵表示(shi)確(que)(que)認(ren),按鍵后儀器進入(ru)測量狀態(tai)(tai)。
2.測(ce)量信息的存(cun)儲(chu)、提取和清除
儲(chu)(chu)存(cun)(cun):在(zai)測(ce)試(shi)過程(cheng)中(zhong),如(ru)果需(xu)要(yao)儲(chu)(chu)存(cun)(cun)某一測(ce)量(liang)(liang)值,只要(yao)短按“儲(chu)(chu)存(cun)(cun)/提取”鍵即可,此時顯示(shi)屏會出(chu)現“STORE”字符(fu)和(he)儲(chu)(chu)存(cun)(cun)編(bian)號(hao)(1、2、3、4-25),表示(shi)該測(ce)量(liang)(liang)值已(yi)在(zai)此編(bian)號(hao)下(xia)儲(chu)(chu)存(cun)(cun),并馬(ma)上返回正常顯示(shi)模式,本(ben)儀器可儲(chu)(chu)存(cun)(cun)25個測(ce)量(liang)(liang)值,如(ru)儲(chu)(chu)存(cun)(cun)超過25個,*個儲(chu)(chu)存(cun)(cun)的測(ce)量(liang)(liang)值將(jiang)被依次替換。
提(ti)取(qu):按(an)住“儲(chu)(chu)存/提(ti)取(qu)”鍵(jian)數秒鐘,待(dai)顯(xian)(xian)(xian)示(shi)(shi)(shi)屏(ping)出現“RECALL”字符和儲(chu)(chu)存編(bian)號時松開,顯(xian)(xian)(xian)示(shi)(shi)(shi)屏(ping)即顯(xian)(xian)(xian)示(shi)(shi)(shi)測量值,此時顯(xian)(xian)(xian)示(shi)(shi)(shi)的(de)是(shi)zui后儲(chu)(chu)存的(de)編(bian)號和測量,再按(an)*鍵(jian),可(ke)依次顯(xian)(xian)(xian)示(shi)(shi)(shi)儲(chu)(chu)存編(bian)號及測量值。在(zai)短按(an)確認鍵(jian)即退也提(ti)取(qu)程序,RECALL字符消失,儀器(qi)返回正(zheng)常顯(xian)(xian)(xian)示(shi)(shi)(shi)模式(shi).
清除:在“RECALL”狀態下(xia),按(an)住確認鍵(jian)5秒鐘,即可(ke)清除所有儲(chu)存的(de)數據。
精密臺式電導率儀常規使用(yong)
根據(ju)所測溶液選用適(shi)當(dang)的(de)電極,把(ba)電極插(cha)(cha)(cha)(cha)頭(tou)(tou)插(cha)(cha)(cha)(cha)入插(cha)(cha)(cha)(cha)座,使插(cha)(cha)(cha)(cha)頭(tou)(tou)的(de)凹槽(cao)對準插(cha)(cha)(cha)(cha)座的(de)凸槽(cao),按(an)一下插(cha)(cha)(cha)(cha)頭(tou)(tou)的(de)頂部,聽(ting)見“咔”的(de)一聲(sheng)即可。(插(cha)(cha)(cha)(cha)頭(tou)(tou)拔出:捏住插(cha)(cha)(cha)(cha)頭(tou)(tou)往外拔即可)。將電源適(shi)配器(qi)插(cha)(cha)(cha)(cha)入220V交(jiao)流電源,輸出頭(tou)(tou)插(cha)(cha)(cha)(cha)入儀器(qi)后DC9V插(cha)(cha)(cha)(cha)口,按(an)“開機”鍵,接(jie)通(tong)電源,預熱10分鐘。
1.電導率較準
     按“校準(zhun)(zhun)(zhun)”鍵(jian),“CAL”閃爍,提示進入校準(zhun)(zhun)(zhun)模(mo)式(shi),將1408μs/cm標(biao)準(zhun)(zhun)(zhun)標(biao)定頭插入儀(yi)器(qi)后部(bu)電(dian)極座,等(deng)測量值穩(wen)定,再按“校準(zhun)(zhun)(zhun)”鍵(jian),LCD顯(xian)示閃爍“1408μs/cm” ,幾秒(miao)鐘后顯(xian)示“End”符(fu)號并(bing)返回測量模(mo)式(shi),可重復校準(zhun)(zhun)(zhun)直至測量值穩(wen)定和(he)準(zhun)(zhun)(zhun)確。
注意:儀器出廠(chang)時已進行校準,一般情(qing)況下可直接使用。
2.電導率測量
      將電(dian)(dian)導(dao)電(dian)(dian)極(ji)洗凈并(bing)甩干,放(fang)入溶液中,攪動后靜止(zhi)放(fang)置,等(deng)測(ce)量值(zhi)穩定,即為(wei)該(gai)溶液的電(dian)(dian)導(dao)率值(zhi)。
3.重(zhong)要說明
本儀器內(nei)存以(yi)下二種校準溶液系列,請在參數設(she)置(zhi)P1中設(she)定;
USA(歐美(mei)系(xi)列(lie))—84μs/cm ;1413μs/cm ;12.88ms/cm ;111.9ms/cm 
CH(中(zhong)國系列(lie))—146.6US/CM;1408μs/cm ;12.85ms/cm ;111.3ms/cm 
本(ben)儀器具(ju)備的(de)一(yi)點校(xiao)(xiao)準(zhun)(zhun)(zhun)功能,可按水樣(yang)和(he)校(xiao)(xiao)準(zhun)(zhun)(zhun)溶液的(de)電導(dao)率盡量接近的(de)原(yuan)則選擇一(yi)種校(xiao)(xiao)準(zhun)(zhun)(zhun)溶液進行(xing)校(xiao)(xiao)準(zhun)(zhun)(zhun),一(yi)般常用(yong)(yong)的(de)校(xiao)(xiao)準(zhun)(zhun)(zhun)溶液是1408μs/cm ,使用(yong)(yong)本(ben)儀器配套的(de)電導(dao)電極(ji)(K=1cm-1),用(yong)(yong)1408μs/cm校(xiao)(xiao)準(zhun)(zhun)(zhun)溶液進行(xing)校(xiao)(xiao)準(zhun)(zhun)(zhun),可以在小(xiao)于100ms/cm的(de)測量范圍內使用(yong)(yong)。請參考表(biao)(1-1)進行(xing)選擇。
表(biao)(1-1)
測量(liang)范(fan)圍    0.1~20μs/cm    0.5μs/cm ~ 200ms/cm
電極(ji)常(chang)數    K=0.1cm-1     K=1.0 cm
校準溶(rong)液    146.6μs/cm    146.6μs/cm    1408μs/cm    12.85μs/cm
111.3Ms/cm
儀器(qi)設置的(de)電(dian)(dian)導(dao)電(dian)(dian)極(ji)校準(zhun)(zhun)(zhun)方法(fa)(fa)(fa)(fa)有(you)標準(zhun)(zhun)(zhun)溶液校準(zhun)(zhun)(zhun)法(fa)(fa)(fa)(fa),標準(zhun)(zhun)(zhun)校準(zhun)(zhun)(zhun)座(zuo)1408μs/cm和(he)常數設定(ding)法(fa)(fa)(fa)(fa)三種(zhong),標準(zhun)(zhun)(zhun)溶液校準(zhun)(zhun)(zhun)法(fa)(fa)(fa)(fa),只要標準(zhun)(zhun)(zhun)溶液是準(zhun)(zhun)(zhun)確(que)的(de),它(ta)就能保證準(zhun)(zhun)(zhun)確(que)度。用(yong)戶如習慣采用(yong)常數設定(ding)法(fa)(fa)(fa)(fa),即根(gen)據(ju)電(dian)(dian)導(dao)電(dian)(dian)極(ji)上標注的(de)常數值進行設定(ding)的(de)方法(fa)(fa)(fa)(fa),試(shi)樣座(zuo)校準(zhun)(zhun)(zhun)法(fa)(fa)(fa)(fa)是我公(gong)司(si)的(de)創新發明(ming),使用(yong)時非常方便快捷,三種(zhong)校準(zhun)(zhun)(zhun)方法(fa)(fa)(fa)(fa)可以任意選用(yong),不會相互(hu)影響。
    儀(yi)器(qi)出廠(chang)設(she)(she)置的溫度補償系數(shu)是2.0%/℃,但是各種(zhong)不同(tong)種(zhong)類(lei)和不同(tong)濃度溶液(ye)的電導率(lv)溫度系數(shu)各不相同(tong),用戶可參考(kao)表(1-2)以及在實驗中(zhong)得到的數(shu)據,在參數(shu)設(she)(she)置P3中(zhong)進行設(she)(she)定。
注意(yi):當將溫度(du)補償系數設置為0.00時(shi)(shi),即儀器測(ce)試時(shi)(shi)無溫度(du)補償,儀器的測(ce)量值是當時(shi)(shi)溫度(du)下的電導率值.
表(1-2)
溶(rong)液(ye)    溫(wen)度補償系(xi)數
NaCl鹽(yan)溶液    2.12%/℃
5%NaOH    1.72%/℃
稀氨水(shui)溶液    1.88%/℃
10%鹽酸溶(rong)液    1.32%/℃
5%硫酸溶液(ye)    0.96%/℃
儀器的(de)其它(ta)參數設置內容,請(qing)參見(jian)表(biao)(1-3)
4.參(can)數設置
電(dian)導率測試(shi)參數(shu)設(she)置一覽表(1-3)
表(1-3)
提示符    參(can)數設(she)置(zhi)項(xiang)目    參(can)數
P1    標準溶(rong)液系列選擇(ze)    USA(歐美系列)—84μs/cm ;1413μs/cm ;12.88ms/cm;111.9ms/cm
CH(中國(guo)系列(lie))—146.6US/CM;1408μs/cm ;12.85ms/cm;111.3ms/cm
P2 ;   電極常(chang)數選(xuan)擇    0.1,1,10
P3    溫度補償系數設(she)置    0.00~9.99%
P4    電極常數設定     
P5    溫度(du)單位(wei)選擇    ℃和0F
P6    恢復出廠設(she)置    OFF---On (關閉—設(she)置)
(1)電導率校準溶(rong)液系列選擇(P1)
○1按(an)“功能”鍵(jian),儀器進入(ru)P1模式;
○2按“∧”或“∨”鍵選擇標準溶液系列(lie);
      CH-中國系列(lie)  USA-歐美系列(lie)
○3按“功能”鍵進入下一項參數設置或按“確認”并返回測量模式(shi);
(2)電極(ji)常(chang)數(shu)選擇(ze)(P2)
○1在P模式(shi)(shi)下按“功能鍵”進入P2模式(shi)(shi);
○2按“∧”或(huo)“∨”鍵改變常數設置:0.1→1→10;
○3按“功能(neng)”鍵(jian)進入下一項(xiang)參(can)數設置或(huo)按“確認(ren)”鍵(jian)確認(ren)并返回測(ce)量模式;
○4P2的(de)出廠設(she)置為(wei)K=1;
(3)溫度(du)補償系數設置(P3)
○1在P2模(mo)式(shi)下按(an)“功能”鍵進入P3模(mo)式(shi);
○2按“∧”或“∨”鍵數字改(gai)變范圍(wei):0.00-9.99;長按“∧“或“∨”鍵,可快速改(gai)變;
注意:當設(she)定(ding)數字(zi)為0.00時,表(biao)示沒有溫(wen)度補償;
○3按(an)“功能”鍵(jian)進入(ru)下(xia)一項參數(shu)設置或按(an)“確(que)(que)認(ren)”鍵(jian)確(que)(que)認(ren)并返回(hui)測量(liang)模式;
P3的了廠(chang)設置是2.0%;
(4)電極常數(shu)設定(P4)
○1在P3模(mo)式下按(an)“功(gong)能”鍵進入P4模(mo)式,LCD顯示前一(yi)次校準的(de)常數(shu)值;
○2按“∧”或(huo)“∨”鍵修改大小,根據(ju)電(dian)導電(dian)極上(shang)標(biao)記(ji)的常(chang)數值進(jin)行(xing)設定;
○3按“功能”鍵(jian)進入下(xia)一項參數設置或按“確認(ren)”鍵(jian)確認(ren)并返回(hui)測量模式;
○4如(ru)需(xu)對常(chang)數(shu)1以外的(de)電導電極進行(xing)常(chang)數(shu)設(she)(she)定(ding),例如(ru)使用常(chang)數(shu)10.3的(de)電導電極,應入(ru)常(chang)數(shu)設(she)(she)置(zhi)P2中(zhong)設(she)(she)定(ding)常(chang)“10”,然后(hou)再進入(ru)P4模式將(jiang)常(chang)數(shu)值設(she)(she)定(ding)為10.3;
(5)溫度單位選擇(P5)
○1在P4模式下按“功(gong)能”鍵進入P5模式;
○2按“∧”或“∨”鍵可選(xuan)擇溫度單位℃或0F;
○3按“功能”鍵(jian)進入下(xia)一項參數設置或按“確認”鍵(jian)確認并返(fan)回測量模式;
(6)恢復出廠設(she)置(P6)
○1在P5模式下按“功能(neng)”鍵,進入P6模式;
○2按“∧”或“∨”鍵選擇“On”,表示恢復出廠(chang)設置模式,2S后返回測量模式;
五、注意事項
1.儀器出廠時已對電導(dao)電極進(jin)行校準(zhun),一般情況下用戶(hu)可直接使(shi)用。
2.正常使(shi)(shi)用(yong)(yong)(yong)情況下推薦每月校準(zhun)一(yi)次;新購(gou)的(de)(de)電(dian)(dian)導電(dian)(dian)極,以及使(shi)(shi)用(yong)(yong)(yong)一(yi)段時間后的(de)(de)電(dian)(dian)導電(dian)(dian)極應進(jin)行校準(zhun)。3.保持電(dian)(dian)導電(dian)(dian)極的(de)(de)清潔,測(ce)(ce)量前后要(yao)用(yong)(yong)(yong)純(chun)水沖洗(xi)電(dian)(dian)極并甩干,再用(yong)(yong)(yong)被(bei)測(ce)(ce)溶液沖洗(xi)電(dian)(dian)極。
4.電(dian)導電(dian)極(ji)的感應棒表面(mian)鍍有一層金屬鉑(bo)黑,用(yong)以降(jiang)低(di)電(dian)極(ji)極(ji)化,擴 程(cheng),因此鉑(bo)黑電(dian)極(ji)表面(mian)不能(neng)擦(ca)拭,只能(neng)在水(shui)中晃動(dong)清洗(xi),以免損壞鉑(bo)黑鍍層;用(yong)含有洗(xi)滌劑的溫熱水(shui)可(ke)以清洗(xi)電(dian)極(ji)上有機成分沾污,也可(ke)以用(yong)酒精清洗(xi)。
5.電(dian)導(dao)電(dian)極(ji)(ji)平(ping)時應浸在純(chun)(chun)水中,以防止鉑黑(hei)(hei)的(de)惰化(hua),如發(fa)現(xian)鍍(du)鉑黑(hei)(hei)的(de)電(dian)極(ji)(ji)失靈,可浸入10%硝酸(suan)溶液或10%鹽酸(suan)溶液中2min,然(ran)后用純(chun)(chun)水沖洗干凈再(zai)測量(liang),如情況并(bing)無(wu)改善(shan),則鉑黑(hei)(hei)要重新(xin)(xin)電(dian)鍍(du),或更換新(xin)(xin)的(de)電(dian)導(dao)電(dian)極(ji)(ji)。
6.當儀(yi)器出現不正常時,請設(she)置(zhi)P6為“On”,使儀(yi)器恢(hui)復出廠(chang)設(she)置(zhi)狀態,再(zai)進行校準和(he)測試。
儀器成套      
1.DDS-307臺式微(wei)機型電(dian)導率(lv)儀 1臺
2.DJS-1E(鉑黑)電(dian)極 1支
3.1408μs/cm電導率標準校準座 1支
4.9V電源適配器(qi) 1支
5.電(dian)極(ji)架及電(dian)極(ji)夾(jia) 1套
6.使用手冊(ce) 1本
7.產品保修(xiu)卡 1份
8.產品合(he)格證 1份

產品咨詢

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請(qing)輸入計算(suan)結(jie)果(填寫阿拉伯數字),如:三加(jia)四=7